DSB01C - Legacy Double Ended Shear Beam Load Cell (5,000 lbs - 250,000 lbs)

DSB01C - Legacy Double Ended Shear Beam Load Cell (5,000 lbs - 250,000 lbs)

The Hardy DSB01C Double Ended Shear Beams are Legacy Stainless Steel or Alloy Steel load cells designed for use on medium to high capacity tanks, hoppers, or vessels. This series offers high accuracy and reliable performance with Hardy’s industry-leading C2 Electronic Calibration technology. Due to their legacy status, a minimum of 10 order pieces per SKU is required and they may be subject to longer lead times.

Or call 858.278.2900 for assistance

The Hardy DSB01C Double Ended Shear Beam load cells and MDSB01C  mounting hardware are designed for use on medium to high capacity tanks, hoppers, or vessels. This series offers high accuracy and reliable performance with Hardy’s industry-leading C2 Electronic Calibration technology.

Ideal for high-capacity tanks and vessels, the DSB01C and mounts series are dependable workhorses suitable for heavy-duty applications. The load cells are either alloy steel  or stainless steel ) construction. Both Stainless Steel and Nickel plated alloy steel come in 5Klb to 250Klb (2.27 to 113.4 Metric Tons), with mounting hardware available separately.

They are oil-proof, waterproof, and non-corrosive, making them suitable for all kinds of environments. They have a protection rating of IP67. DSB01C load cells come with a 9m (30 ft) cable.  

Due to their legacy status, a minimum of 10 order pieces per SKU is required and they may be subject to longer lead times.

SPECIFICATIONS                 DSB01C-SS                 DSB01C-AS
Rated Output (ES)               3±0.003mV/V             3±0.003mV/V
Max # Verification Int.         3000                           3000
Min Verification Int.             Emax/7500                  Emax/12500
Zero Balance                        <±1.0 % R.O.              <±1.0 % R.O.
Combined Error                   <±0.023 % R.O.          <±0.023 % R.O.
Input Resistance                  700±7 ohm                700±7 ohm
Output Resistance               703 ± 4 ohm              703 ± 4 ohm
Insulation Resistance    >5000 Mohm@50 VDC    >5000 Mohm@50VDC
Excitation                             5 - 12 vdc                      5 - 12 vdc
Safe Load Limit                    150% Emax                   150% Emax
Ultimate Load                      300 % Emax                   300 % Emax
Sensor Material                Stainless Steel 17-4PH    Nickel Plated Alloy Steel
Max Anti Rotation                40% Emax                      40% Emax
Max Anti Side Loading         20% Emax                      20% Emax
Max Vertical Lifting           5-20Klb: 3.3K (1.5mt)         5-20Klb: 3.3K (1.5mt) 
                                          30-75Klb: 11K (5 mt)          30-75Klb: 11K (5 mt)
                                         100-150Klb: 16.5K (7.5mt)  100-150Klb: 16.5K (7.5mt)
                                          200-250Klb: 68K (31 mt)    200-250Klb: 68K (31 mt)
Sealing                              Potted                                  Potted
Approvals                          CE, IP67                               CE, IP67
Warranty                           Two years                            Two years

Stainless Steel DSB01C Load Cells

Model Number Mount Capacity C2® Cable Weight
DSB01C-SS-5KLB MDSB01C-SS-5-20KLB 5,000 Lbs. 2,268 Kg Yes 30' 5 Lbs.
DSB01C-SS-10KLB MDSB01C-SS-5-20KLB 10,000 Lbs. 4,536 Kg Yes 30' 5 Lbs.
DSB01C-SS-20KLB MDSB01C-SS-5-20KLB 20,000 Lbs. 9,072 Kg Yes 30' 5 Lbs.
DSB01C-SS-30KLB MDSB01C-SS-30-75KLB 30,000 Lbs. 13,608 Kg Yes 30' 7 Lbs.
DSB01C-SS-50KLB MDSB01C-SS-30-75KLB 50,000 Lbs. 22,680 Kg Yes 30' 16 Lbs.
DSB01C-SS-60KLB MDSB01C-SS-30-75KLB 60,000 Lbs. 27,216 Kg Yes 30' 16 Lbs.
DSB01C-SS-75KLB MDSB01C-SS-30-75KLB 75,000 Lbs. 34,019 Kg Yes 30' 16 Lbs.
DSB01C-SS-100KLB MDSB01C-SS-100KLB 100,000 Lbs. 45,359 Kg Yes 30' 24 Lbs.
DSB01C-SS-150KLB MDSB01C-SS-150KLB 150,000 Lbs. 68,039 Kg Yes 30' 24 Lbs.
DSB01C-SS-200KLB MDSB01C-SS-200-250KLB 200,000 Lbs. 90,718 Kg Yes 30' 46 Lbs.
DSB01C-SS-250KLB MDSB01C-SS-200-250KLB 250,000 Lbs. 113,398 Kg Yes 30' 46 Lbs.

Alloy Steel DSB01C Load Cells

Model Number Mount Capacity C2® Cable Weight
DSB01C-AS-5KLB MDSB01C-AS-5-20KLB 5,000 Lbs. 2,268 Kg Yes 30' 5 Lbs.
DSB01C-AS-10KLB MDSB01C-AS-5-20KLB 10,000 Lbs. 4,536 Kg Yes 30' 5 Lbs.
DSB01C-AS-20KLB MDSB01C-AS-5-20KLB 20,000 Lbs. 9,072 Kg Yes 30' 5 Lbs.
DSB01C-AS-30KLB MDSB01C-AS-30-75KLB 30,000 Lbs. 13,608 Kg Yes 30' 7 Lbs.
DSB01C-AS-50KLB MDSB01C-AS-30-75KLB 50,000 Lbs. 22,680 Kg Yes 30' 16 Lbs.
DSB01C-AS-60KLB MDSB01C-AS-30-75KLB 60,000 Lbs. 27,216 Kg Yes 30' 16 Lbs.
DSB01C-AS-75KLB MDSB01C-AS-30-75KLB 75,000 Lbs. 34,019 Kg Yes 30' 16 Lbs.
DSB01C-AS-100KLB MDSB01C-AS-100KLB 100,000 Lbs. 45,359 Kg Yes 30' 24 Lbs.
DSB01C-AS-150KLB MDSB01C-AS-150KLB 150,000 Lbs. 68,039 Kg Yes 30' 24 Lbs.
DSB01C-AS-200KLB MDSB01C-AS-200-250KLB 200,000 Lbs. 90,718 Kg Yes 30' 46 Lbs.
DSB01C-AS-250KLB MDSB01C-AS-200-250KLB 250,000 Lbs. 113,398 Kg Yes 30' 46 Lbs.

DSB01C Mounting Hardware Stainless Steel

Model Number Compatible Sensor Capacity Finish Weight
MDSB01C-SS-5-20KLB 5,000 Lbs. - 20,000 Lbs. Stainless 30 Lbs.
MDSB01C-SS-30-75KLB 30,000 Lbs. - 75,000 Lbs. Stainless 90 Lbs.
MDSB01C-SS-100KLB 100,000 Lbs. Stainless 170 Lbs.
MDSB01C-SS-150KLB 150,000 Lbs. Stainless 170 Lbs.
MDSB01C-SS-200-250KLB 200,000 Lbs. - 250,000 Lbs. Stainless 720 Lbs.

DSB01C Mounting Hardware Alloy Steel

Model Number Compatible Sensor Capacity Finish Weight
MDSB01C-AS-5-20KLB 5,000 Lbs. - 20,000 Lbs. Plated 30 Lbs.
MDSB01C-AS-30-75KLB 30,000 Lbs. - 75,000 Lbs. Plated 90 Lbs.
MDSB01C-AS-100KLB 100,000 Lbs. Plated 170 Lbs.
MDSB01C-AS-150KLB 150,000 Lbs. Plated 170 Lbs.
MDSB01C-AS-200-250KLB 200,000 Lbs. - 250,000 Lbs. Plated 720 Lbs.

The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including C2® electronic calibration, and Integrated Technician® to name just a few.

Hardy load cells support the following Hardy Process Toolbox functions when coupled with a Hardy Instrument and Hardy C2® cable.

C2® (or eCAL) Electronic Calibration

The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.

INTEGRATED TECHNICIAN® Operator Diagnostics

Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.