The Hardy Process Solutions HI SPA Series of aluminum single point load cells are designed for the OEM, conveyor, and bench scale markets, which can accommodate off center loads. They are built to perform in industrial packaging, dispensing, and dosing applications. These aluminum sensors come standard with C2® calibration capabilities.
The HI SPA42 comes in capacities from 11lbs to 440lbs (5kg to 200kg), is environmentally rated at IP67, and has improved potting. The HI SPA42 has 3 meters of cable (9.8 ft.).
Capacities: 11/22/44/66/110/200/400 lbs (5/10/20/30/50/100/200 kg)
SPECIFICATIONS |
HI SPA42 |
Rated Output (ES) |
2±10% mV/V |
Max # Verification Int. |
3000 |
Min Verification Int. |
Emax/6000 |
Non-Linearity |
<±0.0166 % R.O. |
Hysteresis |
<±0.0166 % R.O. |
Zero Balance |
<±5.0 % R.O. |
Combined Error |
<±0.02 |
Creep @ 30 Min. |
<±0.0166 % R.O. |
Temp Effect Output |
<±0.0140 % R.O./C |
Temp Effect Sensitivity |
<±0.010 % R.O./C |
Input Resistance |
413 ± 20 ohm |
Output Resistance |
350 ± 25 ohm |
Insulation Resistance |
≥5000 Mohm |
Excitation |
5 - 15 vdc |
Safe Load Limit |
150 % Emax |
Ultimate Load |
300 % Emax |
Safe Side Load |
100 % Emax |
Material |
Aluminum |
Sealing |
Potted |
IP Rating |
IP67 |
Hazardous |
FM IS Class 1, Div 1 |
Warranty |
Two years |
The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including C2® electronic calibration, and Integrated Technician® to name just a few.
Hardy load cells support the following Hardy Process Toolbox functions when coupled with a Hardy Instrument and Hardy C2® cable.
C2® (or eCAL) Electronic Calibration
The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.
INTEGRATED TECHNICIAN® Operator Diagnostics
Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.